| Step 1
Documentation
ADVACO can arrange transport of your equipment to our facility,
where your pump is then issued a work order number. From this
point on, we document the status and details of your pump
throughout the entire remanufacture process.
Detailed data outlining failure analysis, parts required,
and test results reinforces a comprehensive servicing of your
pump and provides a detailed record for future reference.
Customized quarterly and/or annual reports can be generated
upon request to aid in tracking overall repair histories and
expenditures.
Step 2
Disassembly
The ADVACO facility is equipped to provide an EPA-compliant,
environmentally secure setting both for our employees as well
as your vacuum equipment.
Once the documentation process has been initiated, your pump
is completely disassembled and immediately transferred to
our automated cleaning system – no solvents, CFCs, or
EPA-banned chemicals are used.
Only high-temperature water and semiconductor-compatible
water-based detergents are used to agitate and remove all
process residue deposited on your pump. This thorough cleaning
enables our technicians to accurately inspect each individual
pump part.
Step 3
Evaluation
ADVACO’s complete evaluation of your
pump is free of charge. We inspect each pump component and
deliver a comprehensive quote and detailed failure analysis
report for your review.
- All consumable parts are quoted for replacement (as applicable)
– gaskets, o-rings, valves, seals, springs, bushings,
claws, etc.
- Additional parts are quoted for replacement or remanufacture
in our machine shop.
- Motors are bench-checked for proper operation and performance.
- Upon receiving your approval, you pump undergoes a second
cleaning to remove any final contaminants before reassembly
begins.
Step 4
Assembly
ADVACO’s skilled technicians recreate the assembly techniques
of your pump’s original manufacturer, using the specific
tolls and fixtures necessary to restore like-new performance.
Our extensive experience and exacting procedures often result
in a rebuilt pump that performs better and lasts longer then
new.
Step 5
Testing
ADVACO has developed a set of specific test criteria that
every pump must meet before return shipment. We utilize calibrated
computerized testing equipment to verify the following against
OEM and ADVACO standards.
- Operating temperature
- Vibration
- Noise
- Motor amperage
- Pumping speed
- Gas flow
- Ultimate vacuum
- Leakage
- Coolant and purge gas flow
- Sensor operation
|