Vacuum Pump Oil Flitration Systems vacuum pump troubleshooting
   
Cryogenic Vacuum Pump and Compressor Repair Services
 
vacuum pump rebuild process
 
Cryo Vacuum Pump Repair Services
CTI -Cryogenics
Vacuum Pump
Advanced Vacuum Company offers extensive repair services for your CTI cryogenic cold-heads. Models serviced include standard, flat, and on-board configurations.

Every cryogenic cold-head rebuild begins with complete disassembly and decontamination. Once thoroughly cleaned our technicians will inspect all pump parts for wear or damage. The standard rebuild of your cold-head will include a complete rebuilding of the drive unit and displacer assembly. The following components will be replaced during a standard rebuild:

  • Displacer seals
  • Set screws
  • Gland retaining ring
  • Driver retaining ring
  • Kap seal
  • Bearings
  • Guide pin and plug assembly
  • Rocker arm bushings
  • Compression springs
  • Indium gaskets
  • New 15K charcoal array
  • Scotch yoke gland
  • O-rings
  • Displacer pin
  • Bushings
  • Dowel pi
  • Stop nut
  • Teflon seal
  • Valve springs
Cryo Cold-Head Rebuild Kit
If any major component damage is detected it will be noted on the failure analysis report and quoted to you upon the completion of the evaluation. After approval of the quoted rebuild our factory trained technicians will reassemble your pump with the components listed above and it will be tested for a minimum period of 24 hours. A computer print out of the test report will be returned with the rebuilt pump.

All ADVACO cryogenic pump rebuilds are covered by our exclusive one year warranty, from the date of installation, against defects in parts and workmanship.

Cryogenic Compressor Repair Services
In order to keep your complete cryogenic system operating properly, ADVACO also offers repair services for your CTI cryogenic compressors. All compressors can be serviced, from the older SC compressor to the latest CTI models. ADVACO’s scope of repair for CTI cryo compressor includes:

  • Evacuation of helium lines
  • Bake out lines
  • Backfill with helium
  • Change compressor oil
  • Leak check unit (for oil and/or gas leaks)
  • Replace adsorber
  • Troubleshoot and repair compressor as needed
  • Troubleshoot and repair electrical system as needed
  • Repair/replace damaged fittings as needed

All cryo compressor repairs are quoted upon evaluation and based on the parts and labor necessary to restore proper performance. ADVACO warrants that all materials and labor pertaining to the specific repairs performed during the time of service shall be free of defects in parts and workmanship for a period of one year. Failure of components unrelated to a previous repair, are not covered under warranty.




Ranks Advanced Vacuum Co, Inc.
as one of the Top 25 Growing
Small to Midsized Manufacturers
Advanced Vacuum Company, Inc.
1215 Business Parkway North, Westminster, MD 21157
1-800-272-2525 (410) 876-8200 FAX (410) 876-5820

ISO 9001:2000